Losing Pressure on your Pressure Cleaner or Drain Cleaner?

Kerrick
Have you lost pressure on your pressure cleaner or drain cleaner and have no idea why? This is a problem we hear about every day at Kerrick. Australians are practical people and most of the time by working your way through this handy checklist we've compiled below for you, you’ll be able to figure out what’s going on with your jetting equipment.
POSSIBLE CAUSE
Nozzle is worn or you’re using the wrong size. If your nozzle is worn or too big, the hole the water passes through is larger than it should be and therefore provides less resistance. Less resistance equals less pressure.
SOLUTION
Replace with a correctly sized new nozzle. If you’re not sure which nozzle size is the best fit for your equipment come chat to the team at Kerrick and they’ll do the calculations and set you up with the right equipment.
POSSIBLE CAUSE
Low water supply. A lower flow of water means the pump will not get to the required pressure and it will “cavitate” causing damage and ultimately complete failure. It’s extremely important to maintain a constant and adequate supply of water to the pump.
SOLUTION
  • Check water tank is full / tap is turned on.
  • Check for any leaks or obstructions to the flow of water into the pump.
  • Check manual to ensure inlet port and line OD are correct and aren’t restricting the water flow.
  • Flush hoses/lines in gravity fed systems.
POSSIBLE CAUSE
Faulty Unloader. Check to see if the unloader is by-passing water back to the tank or pump head properly (unloaders help to regulate pressure).
SOLUTION
  • Check condition of the seal at ball and seat.
  • Check for any obvious damage.
POSSIBLE CAUSE
Faulty Regulator. A regulator is a pressure control valve that sets and maintains system pressure. A worn or “stuck” piston can cause excess bypass flow and low system pressure.
SOLUTION
Strip the regulator and check for wear/restricted movement in the piston valve assembly. Depending on damage either clean and repair or replace the internal piston.
POSSIBLE CAUSE
Worn or dirty valves and seals. Damaged valves and seals result in lower flow and pressure overall.
SOLUTION
Check and replace as needed.
POSSIBLE CAUSE
Pump not turning. If the pump doesn't turn, there will be no flow.
SOLUTION
  • Check for key in shaft and replace as needed.
  • Check for belt slippage.
  • Check electric motor or engine for faults.
POSSIBLE CAUSE
Belt slippage. Belt slippage results in the pump running at a lower RPM, which in turn affects pump output. Less flow equals less resistance, which equals less pressure.
SOLUTION
Check belt drive assembly and tighten or replace belts as needed.